Tel:. (+34) 93 729 6004     e-mail: web@fema.es

APPLICATION Weight

Weight

APPLICATION Weight

Please enter your email before downloading the document

CONTACT NOW!

Description

Instruments to measure signals from loadcells. Typical 1mV/V, 2mV/V or 3mV/V signals.


Main characteristics

    Segment
  • General industry applications
  • Only for replacements
    Type
  • Signal converter and isolator
    Function
  • Load cells
    Signals accepted
  • mVdc
    Input Ranges
  • 0/30mVdc
  • 0/20mVdc
  • 0/10mVdc
    Output signal
  • 4/20mA
  • 0/10Vdc
    Power
  • 230 Vac
  • 115 Vac
  • 24 Vdc
    Isolation
  • 3500V
    Mounting
  • DIN rail mount
    Connections
  • plug-in screw terminals
    Width
  • 22.5mm
  • 37mm


Series

There are no such models


Models

ISC-LC

ISC-LC

Isolated signal converter for loadcells signals. Din rail mount.


Out and control Options

There are no such options


Special Options

There are no such options


Other Options

There are no such options


Accesories

There are no such accesories


References

CCT-80-0

Isolated signal converter for loadcell signals. Power 230 Vac 50/60 Hz.

CCT-80-1

Isolated signal converter for loadcell signals. Power 115 Vac 50/60 Hz.

CCT-80-2

Isolated signal converter for loadcell signals. Power 24 Vac 50/60 Hz.

CCT-80-3

Isolated signal converter for loadcell signals. Power 48 Vac 50/60 Hz.

CCT-80-6

Isolated signal converter for loadcell signals. Power 24 Vdc Isolated.

ISC-LC-6

Isolated signal converter for loadcells signals. Din rail mount. Power 24 Vdc Isolated.

ISC-LC-0

Isolated signal converter for loadcells signals. Din rail mount. Power 230 Vac 50/60 Hz.

ISC-LC-1

Isolated signal converter for loadcells signals. Din rail mount. Power 115 Vac 50/60 Hz.

MAG-35-80-0

Loadcell meter Power 230 Vac 50/60 Hz.

MAG-35-80-0-SP11

Loadcell meter Power 230 Vac 50/60 Hz.

MAG-35-80-0-SP11-SAR

Loadcell meter Power 230 Vac 50/60 Hz.

MAG-35-80-0-SP21

Loadcell meter Power 230 Vac 50/60 Hz.

MAG-35-80-0-SP21-SAR

Loadcell meter Power 230 Vac 50/60 Hz.

MAG-35-80-0-MPA2

Loadcell meter Power 230 Vac 50/60 Hz.

MAG-35-80-0-SAR

Loadcell meter Power 230 Vac 50/60 Hz.

MAG-35-80-0-RS2

Loadcell meter Power 230 Vac 50/60 Hz.

MAG-35-80-0-RS4

Loadcell meter Power 230 Vac 50/60 Hz.

MAG-35-80-0-SDA111

Loadcell meter Power 230 Vac 50/60 Hz.

MAG-35-80-1

Loadcell meter Power 115 Vac 50/60 Hz.

MAG-35-80-1-SP21

Loadcell meter Power 115 Vac 50/60 Hz.

MAG-35-80-1-SP21-SAR

Loadcell meter Power 115 Vac 50/60 Hz.

MAG-35-80-1-HM

Loadcell meter Power 115 Vac 50/60 Hz.

MAG-35-80-1-SAR

Loadcell meter Power 115 Vac 50/60 Hz.

MAG-35-80-2

Loadcell meter Power 24 Vac 50/60 Hz.

MAG-35-80-2-HM

Loadcell meter Power 24 Vac 50/60 Hz.

MAG-35-80-3

Loadcell meter Power 48 Vac 50/60 Hz.

MAG-35-80-3-SP21

Loadcell meter Power 48 Vac 50/60 Hz.

MAG-35-80-6

Loadcell meter Power 15/30 Vdc Isolated.

MAG-35-80-6-SP11

Loadcell meter Power 15/30 Vdc Isolated.

MAG-35-80-6-SP11-SAR

Loadcell meter Power 15/30 Vdc Isolated.

MAG-35-80-6-SP21

Loadcell meter Power 15/30 Vdc Isolated.

MAG-35-80-6-SP21-MPA2

Loadcell meter Power 15/30 Vdc Isolated.

MAG-35-80-6-SP21-SAR

Loadcell meter Power 15/30 Vdc Isolated.

MAG-35-80-6-SAR

Loadcell meter Power 15/30 Vdc Isolated.

MAG-35-80-6-RS2

Loadcell meter Power 15/30 Vdc Isolated.

MAG-35-80-8

Loadcell meter Power 24/65 Vdc Isolated.