We are glad to advice the availability of our new M40-P (improved 2012 version) panel meter, suitable to measure process signals.
The M40-P panel meter accepts process signals 4/20mA, 0/10Vdc, ±20mA and ±10Vdc with 4 or 5 digit display (99990 / -99990). Excitation voltage has been improved to a configurable +5Vdc, +10Vdc, +15Vdc, +20Vdc, accuracy has been improved to 0.05% FS with and without excitation voltage, thermal drift has been improved to 10ppm/ºC offset and 25ppm/ºC span, and the unit now supports up to 3 optional modules. Additionally, the display provides segment linearization and the standard functionality common to the M40 series of instruments, such as memory of maximum and minimum, password, relay with activation window (dual setpoints), brightness levels, … The M40-P is one more step in our newest range of M40 programable panel meters.
All M40 meters are manufactured with multiple functionalities, which will help personalize the instrument behaviour to match your application needs. For more information technical or commercial, do not hesitate to contact us and our technical sales team will support you in your needs.
M40-P panel meter, for process signals
SERIES M40 OF PROGRAMMABLE PANEL METERS
Digits. . . . . . . . . . . . . . . . . . 4 digits (optional fifth digit fixed to zero, by menu)
Maximum reading. . . . . . . 9999 (99990)
Minimum reading. . . . . . . -9999 (-99990)
Signals accepted . . . . . . . Process
Ranges. . . . . . . . . . . . . . . . 4/20mA, 0/10Vdc, ±20mA, ±10Vdc
Accuracy . . . . . . . . . . . . . . . 0.05% FS
Excitation voltage. . . . . . . . yes, selectable at +5Vdc, +10Vdc, +15vdc, +20Vdc
Refresh. . . . . . . . . . . . . . . . 15 / second
Acquisitions. . . . . . . . . . . . 15 / second
Thermal drift . . . . . . . . . . . 10ppm/ºC offset
Thermal drift . . . . . . . . . . . 25ppm/ºC span + offset
Configuration . . . . . . . . . . 3 front buttons, rear side jumpers
Included functions
. . . . . . . . . . . . . . . . . . . . . . -segment linearization
. . . . . . . . . . . . . . . . . . . . . . -fixed digits
. . . . . . . . . . . . . . . . . . . . . . -recursive filter
. . . . . . . . . . . . . . . . . . . . . . -steps
. . . . . . . . . . . . . . . . . . . . . . -memory of maximum
. . . . . . . . . . . . . . . . . . . . . . -memory of minimum
. . . . . . . . . . . . . . . . . . . . . . -left zeros
. . . . . . . . . . . . . . . . . . . . . . -add zero to the right
. . . . . . . . . . . . . . . . . . . . . . -password
. . . . . . . . . . . . . . . . . . . . . . -measure function
. . . . . . . . . . . . . . . . . . . . . . -span auto correction
. . . . . . . . . . . . . . . . . . . . . . -offset auto correction
. . . . . . . . . . . . . . . . . . . . . . -peak&hold
. . . . . . . . . . . . . . . . . . . . . . -double setpoints (windowed setpoints)
. . . . . . . . . . . . . . . . . . . . . . -brightness
Mechanical and security
Mounting . . . . . . . . . . . . . . panel mount
Connections. . . . . . . . . . . plug-in screw clamp
Front size. . . . . . . . . . . . . . 96x48mm
Deep. . . . . . . . . . . . . . . . . . 91mm (incluiding terminal)
Power “H” . . . . . . . . . . . . . 85 to 265 Vac/Vdc
Power “L”. . . . . . . . . . . . . . 11 to 60 Vdc (and 24/48Vac)
IP protection . . . . . . . . . . . IP54 (front)