Tel:. (+34) 93 729 6004     e-mail: web@fema.es

MODEL M60-LC

Series M

MODEL M60-LC

Digital panel meter - Series M

Datasheet M60-LCSeries M, K, S - Output and control modulesUser's Manual - M60-LCQuick Installacion Guide - M60-LC
Please enter your email before downloading the document

CONTACT NOW!

Description

Digital panel meter for load cells. for all type of industrial applications. Versatile and reliable, offers a wide range of references with a variety of output and control options and accesories. Its modular architecture provides flexibility to replace, add or change any of its internal modules to expand functionality as needed.

Load cells of 1mV/V, 2mV/V and 3 mV/V, and signal ranges up to 100mV. Provides excitation voltage configurable to +5 Vdc or +10 Vdc (max. 140mA) to power up to 8 standard 350 Ohms cells. Scalable reading from 999999 to -199999 with configurable decimal point.

Configurable access to "tare" function and "auto-tare" for automatic tare when removing weight from the cell. Three configurable working modes with up to 60 acquisitions per second and noise rejection to 50 and 60 Hz.


Main characteristics

    Type
  • Digital panel meter
    Function
  • Load cells
  • Weight
    Digits
  • 6
    Signals accepted
  • mVdc
    Input Ranges
  • 0/5 mVdc
  • 0/10 mVdc
  • 0/15 mVdc
  • 0/20 mVdc
  • 0/30 mVdc
  • 0/100 mVdc
    Excitation voltage
  • +5Vdc (max. 140mA)
  • +10Vdc (max. 140mA)
    Digit type
  • 7 segments led
    Digit height
  • 14mm
    Led color
  • Red
    Power
  • 85/265 Vac/dc (isolated)
  • 11/60 Vac/dc + 24-48Vac (isolated)
    Isolation
  • 2500 Veff
  • 1500 Veff
    IP protection
  • IP65 front
    Mounting
  • Panel mount
    Front size
  • 96x48mm front size
    Included functions
  • Fast access configurable menu
  • On power-up
  • On alarm
  • Hysteresis
  • Alarms with configrable delays
  • Display filters
  • Memory of maximum reading
  • Memory of minimum reading
  • 5 configurable brightness levels
  • Password
    Additional functions
  • Function Tare
  • Funtion Auto-tare
  • Function Tare maximum
  • Scale factor
  • Function stock-units
  • Rejection modes
  • Stability alarmas
  • Rear control


Series

There are no such models


Models

There are no such models


Out and control Options

R1

R1

Relay output
T1

T1

Isolated transistor output
SSR

SSR

Isolated output for SSR control
AO

AO

Analog output
RTU

RTU

Modbus RTU retransmission
S2

S2

RS-232 ASCII retransmission
S4

S4

RS-485 ASCII retransmission


Special Options

R4

R4

Module with 4 relay output


Other Options

There are no such options


Accesories

KA96

KA96

Format adapter to 96x96
THM

THM

Benchtop housing
DRA

DRA

DIN rail adapter
KIP

KIP

IP65 front protector
WME

WME

Wall mounting housing.


References

M60-LC-H-AO-AO

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 2x Analog output.

M60-LC-L-R1-AO-S4

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Relay output + 1x Analog output + 1x RS-485 ASCII retransmission.

M60-LC-L-T1

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Isolated transistor output.

M60-LC-L-R1-RTU

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Relay output + 1x Modbus RTU retransmission.

M60-LC-H-R4

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Module with 4 relay output.

M60-LC-H

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated.

M60-LC-H-R1

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Relay output.

M60-LC-H-R1-R1

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 2x Relay output.

M60-LC-H-R1-R1-R1

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 3x Relay output.

M60-LC-H-R1-R1-AO

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 2x Relay output + 1x Analog output.

M60-LC-H-R1-R1-RTU

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 2x Relay output + 1x Modbus RTU retransmission.

M60-LC-H-R1-AO

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Relay output + 1x Analog output.

M60-LC-H-R1-AO-RTU

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Relay output + 1x Analog output + 1x Modbus RTU retransmission.

M60-LC-H-R1-AO-S2

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Relay output + 1x Analog output + 1x RS-232 ASCII retransmission.

M60-LC-H-R1-RTU

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Relay output + 1x Modbus RTU retransmission.

M60-LC-H-AO

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Analog output.

M60-LC-H-R4-AO

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Analog output + 1x Module with 4 relay output.

M60-LC-H-R4-RTU

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Modbus RTU retransmission + 1x Module with 4 relay output.

M60-LC-H-RTU

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x Modbus RTU retransmission.

M60-LC-H-S4

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 85-265 Vac/Vdc isolated. 1x RS-485 ASCII retransmission.

M60-LC-L

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated.

M60-LC-L-R1

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Relay output.

M60-LC-L-R1-R1

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 2x Relay output.

M60-LC-L-R1-R1-R1

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 3x Relay output.

M60-LC-L-R1-R1-AO

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 2x Relay output + 1x Analog output.

M60-LC-L-R1-R1-RTU

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 2x Relay output + 1x Modbus RTU retransmission.

M60-LC-L-R1-AO

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Relay output + 1x Analog output.

M60-LC-L-R1-AO-RTU

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Relay output + 1x Analog output + 1x Modbus RTU retransmission.

M60-LC-L-AO

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Analog output.

M60-LC-L-RTU

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Modbus RTU retransmission.

M60-LC-L-T1-S4-SSR

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x Isolated transistor output + 1x Isolated output for SSR control + 1x RS-485 ASCII retransmission.

M60-LC-L-S4

Panel meter for load cells. 6 digits. Front size 96x48mm. Power 11-60 Vdc (24/48 Vac) isolated. 1x RS-485 ASCII retransmission.